| Title | Vision beyond visual acuity |
| Purpose | To describe aspects of vision beyond measurement of best-corrected visual acuity. |
| Methods | A review focused mainly on measurement of contrast sensitivity and colour vision tests, illustrated with findings from clinical cases. |
| Results | Mainly in the early stages, many ocular conditions cause a decrease in contrast sensitivity and/or colour vision, before best-corrected visual acuity declines. Using specific tests, such deficiencies of contrast sensitivity and colour vision can be picked up early. |
| Conclusion | Contrast sensitivity and colour vision can be evaluated using commonly available tests, and can aid in making a diagnosis in a patient who complains of visual loss whilst best-corrected visual acuity is still within the normal range. |
| Last name | LEROY |
| Initials | BP |
| Department | Dept of Ophthalmology & Ctr for Medical Genetics, Ghent University Hospital and Ghent University |
| City | Ghent |