TitelRestor : Two years of experience
Abstract Nr.138
DoelAfter 2 years of experience with Alcon Acrysof Restor Apodized Diffractive intra-ocular lens (IOL) (SA60D3) in more than 100 eyes, 25 consecutive refractive candidate patients, bilaterally implanted with the bifocal Restor IOL were evaluated. The optics of this lens are designed to restore near and distance vision.
MethodesFifty eyes of 25 patients had implantation of the SA60D3 IOL in this prospective nonrandomized clinical study. Mean age was 57.84 year (range: 51-74year). Twenty-two eyes were evaluated at 6 months and 50 eyes at 3 months. Patient selection included no other eye disease besides ametropia. Uncorrected distance visual acuity (UCVA-D), uncorrected near visual acuity (UCVA-N), best corrected distance visual acuity (BCVA-D) and distance corrected near visual acuity (DCVA-N) were recorded.
Resultaten23 patients were hyperopic (mean: +2.4 Diopter (D) / range: +0.75D- +6.5D), 2 Patients were myopic (mean: -5.5 D / range: -5D- -6D). Post-operative UCVA-D was better than 20/30 at 3 months and 6 months in 90% of eyes. UCVA-N was equal or better than J3 at 3 months in 96% and all eyes achieved J3 or better at 6 months. Mean post-op refraction was +0.11 D(range: -2.25D - +1.25D). BCVA-D was 20/25 or better in all eyes at 3months. DCVA-N was J2 or better in all eyes at 3 and 6 months. Patients satisfaction and secondary phenomena will be discussed. Two patients needed an additional refractive procedure (LASIK) to correct residual ametropia.
Conclusie3- and 6-month data indicate that refractive lensexchange using the Acrysof Restor Apodized diffractive IOL (SA60D3) to correct ametropia and presbyopia is a safe procedure and provides good uncorrected near and distance visual acuity.
Auteur 1
NaamSALLET
InitialenG
InstituutAlegmeen Stedelijk Ziekenhuis
StadAALST
top ^