| Titre | Long term Clinical outcomes of Refractive Lensectomy in Moderate and High Hyperopia |
| Abstract Nr. | P20 |
| But | To evaluate efficacy, predictability and safety of Refractive lens exchange in moderate to high hyperopia |
| Méthodes | Clinical results are presented of Refractive Lens Exchange in 515 hyperopic eyes with a mean preoperative refraction of +5,29 (+/-1,9)Dptr (range +4 to +12). The mean Axl. eye length was 20,9 mm.(range 16,9-23,O MM.). .The average follow up was 52(+/-27)months:145 eyes were followed for more than 5 years. Clinical results and different calculation formulas were analysed |
| Résultats | Mean refraction improved from +6,29D. preoperatively to 0,24 D. Mean Ucva changed from 0,1(+/-0,08) 20/200 preop.to 0,62(+/-0,24) 20/34 : mean Bcva changed from 0,76(+/-0,22)20/26 preop.to 0,86(+/-0,19) 20/23. Only 1 eye lost two lines . No major complications were seen; specifically not one case of retinal detachment was seen in this large group. The best outcomes were obtained with the TECNIS Mf Iol. Mean errors of different formula’s: Holladay II -0,96(+/-1,29) Dptr.-Srk-Th -2,25(+/-1,59) Th.,Holladay I -1,64(+/-1,49)D. and Hoffer Q-1,24(+/-1,44) Dptr. Using the Srk Th.,Holladay I,Hoffer and Holladay II formula, in respectively 28%,44%,68% and 72% a result of +/_ 1D. intended obtained could be obtained |
| Conclusion | Refractive Lensectomy is an excellent and safe option for treatment of medium to high hyperopia |
| Nom | GOES |
| Initiales | FJ |
| Institut | GOES EYE CENTRE |
| Ville | ANTWERP |