View abstract

Cet abstract a été assigné à session Poster Rapid Fire Presentation
TitreDeposition of pseudoexfoliative material on the surface of an intraocular lens
Abstract Nr.P02
ButTo report a case of pseudoexfoliation (PEX) syndrome with deposition of PEX material on the anterior surface of an acrylic IOL.
RésultatsAn 82-year-old white female presented with bilateral PEX syndrome. Classic PEX deposits were observed on the anterior surface of both lens capsules. An uneventful phacoemulsification was performed on the left eye with implantation of a type 89A (Morcher) IOL by the bag-in-the-lens implantation technique. After 14 months of follow-up, the classic pattern of PEX had reappeared on the anterior surface of the IOL.
ConclusionApart from deposition on many ocular tissues, PEX material can accumulate on acrylic IOL material.
Auteur 1
NomLEYSEN
InitialesLI
InstitutUniversity Hospital Antwerp
VilleEdegem
Auteur 2
NomSmets
InitialesRMES
InstitutUniversity Hospital Antwerp
VilleEdegem
Auteur 3
NomTassignon
InitialesMJT
InstitutUniversity Hospital Antwerp
VilleEdegem